Translate

Showing posts with label Panic alarm. Show all posts
Showing posts with label Panic alarm. Show all posts

Wednesday, 11 November 2015

No Strings!

Now setting the standard are the new Cronapress Disabled Toilet Alarms. Using low level and vertical call points to cover all possible emergencies.  No pull strings to cut or tie up. All areas covered 24/7. 

Disabled Toilet Alarm Strip image

Illuminated call points give assurance the system is working..
Flashing call points means the alarm is activated and help is on its way.
No illumination ? The fault monitoring has detected a fault and sent warning to the control panel. 

Our vandal resistant BS8300 compliant Folknoll manufactured disabled toilet alarm systems provides cost-effective solutions supplied as standard or built as bespoke units. We offer stand-alone toilet alarms, multiple toilet alarms with remote monitoring and combined systems with disabled refuge EVC, fire telephone, building alarms, etc. Interfaces for BMS and transmission over IP are also available. Ideal for shops, offices, hotels, factories and similar locations.
All of our systems are assembled from high quality units tailored for your site.
Our range can be used to construct stand-alone system for single toilets or site-wide systems with multiple monitoring stations, central control stations, BMS interfaces etc. Individual alarms can be grouped and monitored locally and/or from a central monitoring stations. All systems are battery backed for peace of mind during power outages.


Additional options include, remote monitoring over copper / fibre / IP, customised indicator panels, integration with disabled refuge and other alarms, 3rd party interfaces.

Have you covered all risks? Our risk assessment form below will help you not only review your current alarm situation but help chose the correct system to suit your needs.
Click this download link for your own risk assessment PDF copy 
or ring Cronapress 01943 876600 for more details


Check- Reason- Pass?
Full Fault Monitored System Many affray and assurance alarms fail new risk assessment criteria as they are not constantly monitored. Ensure the circuit is linked in series with end of line monitoring.
Click here to find out about combatting interference
 
Fast Press Most affray systems that have end of line monitoring are Fire systems derivatives and have a slow reaction time of over 250ms to 1000ms to overcome nuisance contacts. This is not fit for purpose. Our contact capture time is approximately 10ms and captures the activation. Note 1  
Press not Release to activate Occasionally alarms systems require a press and release to activate. Again this is not acceptable as the strip is unusable if an object is used to keep the strip contact closed.  
Visual Communication If the section to be used can be avoided as visual aids (Not Lit) confirm the area is without affray facilities then risks can be avoided.
See how Cronapress Illumination works here.
 
Robustness In general the weakest link to an affray strip will be the end cap where often the wall mountings are compromised. If the cap is loose or weak issues can arise.
Click here to see how robust Cronapress end caps are.
 
IP65 Specify IP65 where needed -
-
-
-
-
 
Very Low temperature Information required



 


Thursday, 15 May 2014

Cronapress Demonstration Board

Greetings. Cronapressman here.
I've uploaded a short video of our demonstration board. It illustrated the patented illumination in action. The illumination is controlled by our unique PCB that also monitors for End Of Line faults. Providing a clean contact to an alarm system on activation. Of vital importance is the activation speed of the PCB, it will latch on a 10ms contact.
Also visible is the optional conduit adapter that helps not only with ease of installation but also cable management.



Contact us on sales@cronapress.co.uk.
View our products on www.cronapress.co.uk.

Friday, 28 March 2014

Bespoke Switches and Buttons

 Greetings once again to the Cronapress blog.
Today my blog will cover our range of switches and buttons......These are all of 'switchtastic' quality.
That means branded switch gear from recognised sources !!! We use only ITW, Apem and Acal. These are backed up with appropriate specification literature and RoSH compliance.
It makes sense, so don't undermine your own quality standards and values by fitting anything but the best.
Bespoke - We can arrange laser cutting of the backing plate to your own DXF drawings, or we can produce CAD/DXF  drawings and laser too from your sample or sketch.
Usually produced in Brush Finished Stainless DP1, deburred and with countersunk fixing holes as appropriate.
Deep filled engraving available in a variety of colours.
Company logos can be laser etched on plate subject to minimum order.

We generally have in stock PRESS TO EXIT green mushroom button switch plates.

Below are examples of switches produced for customers, but the list is endless, try us.










Cronapressman signing off until next time.
Remember - If it looks right it will be right ! If it doesn't - you guessed it - it won't !